3 functions in 1 probe: measurement of flow, temperature and humidity
Probe head diameter: 12 mm – also suitable for measurements in ventilation ducts
With telescope (can be extended to 745 mm)
Flow measuring range: 0 to +20 m/s
Use the hot wire probe (thermal anemometer) to determine flow velocity and volume flow in ventilation ducts or at ventilation outlets. It is particularly suitable for low and medium flow velocities up to +20 m/s. The probe can also measure temperature and humidity simultaneously.
The hot wire probe is equipped with a telescope, which can be extended to a maximum length of 745 mm.
NTC | |
---|---|
測量范圍 |
-20 ~ +70 °C |
測量精度 |
±0.3 °C |
電容式濕度傳感器 | |
---|---|
濕度測量范圍 |
0 ~ +100 %RH |
測量精度 |
±2 %RH (+2 ~ +98 %RH) |
熱線 | |
---|---|
測量范圍 |
0 ~ +20 m/s |
測量精度 |
±(0.03 m/s + 4 %測量值) |
風(fēng)速 |
---|
技術(shù)參數(shù) | |
---|---|
電纜長度 |
0.8 m |
Length telescope |
745 mm |
Probe head diameter |
12 mm |